EasyManua.ls Logo

Axis Q2901-E - Axis Multicable

Axis Q2901-E
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AXISQ2901-ETemperatureAlarmCamera
Axismulticable
Axismulticable
WhenconnectingexternalequipmenttotheAxisproduct,anAxismulticableisrequiredinordertomaintaintheproduct’sIPrating.
TheAxismulticablecanbepurchasedfromyourAxisreseller.Tolocatethemulti-connector,seeHardwareOverviewonpage7.
Themulticableprovidesthefollowingconnectors:
Powerconnector-2-pinterminalblockusedforpowerinput.Thepolarityofthecablesdoesnotmatter.UseaSafetyExtra
LowVoltage(SELV)compliantlimitedpowersource(LPS)witheitheraratedoutputpowerlimitedto100Woraratedoutput
currentlimitedto5A.
Audioin(pink)-3.5mminputforamonomicrophone,oraline-inmonosignal(leftchannelisusedfromastereosignal).
Audioout(green)-3.5mmoutputforaudio(linelevel)thatcanbeconnectedtoapublicaddress(PA)systemoranactivespeaker
withabuilt-inamplier.Astereoconnectormustbeusedfortheaudioout.
I/Oterminalconnector-Usewithexternaldevicesincombinationwith,forexample,tamperingalarms,motiondetection,event
triggering,timelapserecordingandalarmnotications.Inadditiontothe0VDCreferencepointandpower(DCoutput),theI/O
connectorprovidestheinterfaceto:
DigitaloutputForconnectingexternaldevicessuchasrelaysandLEDs.Connecteddevicescanbeactivatedbythe
VAPIX®ApplicationProgrammingInterface,outputbuttonsontheLiveViewpageorbyanActionRule.Theoutput
willshowasactive(shownunderSystemOptions>Port&Devices>PortStatus)ifthealarmdeviceisactivated.
DigitalinputAnalarminputforconnectingdevicesthatcantogglebetweenanopenandclosedcircuit,for
example:PIRs,door/windowcontacts,glassbreakdetectors,etc.Whenasignalisreceivedthestatechangesand
theinputbecomesactive(shownunderSystemOptions>Port&Devices>PortStatus).
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
DCoutput
2
Canbeusedtopowerauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
12VDC
Maxload=50mA
DigitalinputConnecttopin1toactivate,orleave
oating(unconnected)todeactivate.
0tomax30VDC
Congurable(Input
orOutput)
3–4
DigitaloutputConnectedtopin1whenactivated,
oating(unconnected)whendeactivated.Ifusedwith
aninductiveload,e.g.arelay,adiodemustbeconnected
inparallelwiththeload,forprotectionagainstvoltage
transients.
0tomax30VDC,open
drain,100mA
Foranexamplediagram,seeConnectionDiagramsonpage69.
I/Oconnector
Powerinput
64

Table of Contents

Other manuals for Axis Q2901-E

Related product manuals