AXISQ7411VideoEncoder
Events
Triggers
Availableactionruletriggersandconditionsinclude:
ApplicationsUseinstalledapplicationstotriggertherule.SeeApplicationsonpage32.
-VMD3TriggertherulewhenAXISVideoMotionDetectiondetectsamovingobject.SeeAXISVideoMotion
Detection.
Detectors
-AudioDetectionTriggertherulewhenaudioisdetected.SeeAudioDetectiononpage31.
-TamperingTriggertherulewhentamperingisdetected.SeeCameraTamperingonpage31.
Hardware
-VideoSignalTriggertheruleifvideosignalislost.
-NetworkTriggertheruleifnetworkconnectionislostorrestored.Thiscanforexamplebeusedtostart
recordingtotheSDcard.
-TemperatureTriggertheruleifthetemperaturefallsoutsideorinsidetheoperatingrangeoftheproduct.This
canforexamplebeusedtosendmaintenancenotications.
InputSignal
-DigitalInputPortTriggertherulewhenanI/Oportreceivesasignalfromaconnecteddevice.SeeI/O
Portsonpage58.
-ManualTriggerTriggertheruleusingtheManualTriggerbuttonintheLiveViewpage.SeeControlson
theLiveViewPageonpage11.Thiscanforexamplebeusedtovalidateactionsduringproductinstallation
andconguration.
-VirtualInputscanbeusedbyaVMS(VideoManagementSystem)totriggeractions.Virtualinputscan,for
example,beconnectedtobuttonsintheVMSuserinterface.
PTZ
Storage
-AvailableTriggertherulewhenthestoragedeviceisunmountedorremoved.Thiscanforexamplebeusedto
sendmaintenancenotications.
-DisruptionTriggertheruleifstorageproblemsaredetected,forexampleifthestoragedeviceisunavailable,
removed,full,lockedorifotherreadorwriteproblemsoccur.Thiscanforexamplebeusedtosendmaintenance
notications.
-RecordingTriggerstherulewhentheAxisproductrecordstothestoragedevice.Therecordingstatustrigger
canbeusedtonotifytheoperator,forexamplebyashingLEDlights,iftheproducthasstartedorstoppedto
recordtothestoragedevice.Notethat,thistriggercanbeusedonlyforedgestoragerecordingstatus.
-FullTriggertherulewhenthestoragedeviceisfull.Undernormaloperation,theoldestrecordingswillbe
overwrittentopreventthestoragedevicefrombecomingfull.
-LockedTriggertheruleifthestoragedeviceislocked(writeprotected).
System
-SystemReadyTriggertherulewhentheproducthasbeenstartedandallservicesarerunning.Thiscanfor
examplebeusedtosendanoticationwhentheproductrestarts.