Managethebuilt-inswitch
Theactualpowerconsumedis(5x15)+(3x5)=90W.
Inthisway,allconnecteddevicesareguaranteedenoughpowerandthepriorityislessimportant.
Allocatepowerbyactualconsumption
Whenconnectingadevice,theswitchwillpoweritupifthemaxpowerlimitcanbeensuredatthattime.
FirsttheswitchconnectstovePoEclass4devicesandtheactualconsumptionofpoweris5x15=75W.
Latereachdeviceconsumesupto30Wpower.Theswitchcannotpowervedevicesandtheport5withthelowest
priorityisshutdown.Theactualconsumptionis4x30=120W.
Inthisway,thepriorityoftheportisimportant.Theportwiththelowestprioritywillbeshutdownrstwhenthe
actualconsumptionexceedsthepowerbudget.
Settings
Congurenetworksettings
Youcanchangetheswitch’sIPaddress.Butformostcamerainstallations,werecommendusingthedefaultsettings.Thereasonfor
thisisthatasurveillancenetworkisnormallyisolatedfromothernetworks,forexampleacorporateLAN.Inthiscase,youwould
onlyusethesurveillancenetworktomanageandcollectsurveillancedevicesanddatafromthevideomanagementsoftware
installedontheserver.
1.Intheswitch’smanagementpage,gotoSettings>Networksettings.
2.Entertheconnectiontype,IPaddress,subnetmask,gateway,DNS1,DNS2,andhostname.
Note
Thefactorydefaultsettingsare:astaticIPconnectionwithaddress192.168.0.1andasubnetmaskwithaddress
255.255.255.0.
3.ClickSave.
Conguredateandtime
1.Intheswitch’smanagementpage,gotoSettings>Dateandtime.