TECHNICAL SPECIFICATIONS
Model YGP35-1170ZP
Cooling Capacity (Btu/h)/ W
12.000 Btu/h / 3500 W
Dehumidifying Capacity (l/h) 1.9 l/h
Standard Cooling Input Power/Current
1300 W/5,8A
Air Flow Volume (mΒ³/h) 350 mΒ³/h
Rated Voltage /Frequency (V/Hz) 220-240 V~/50 Hz
Sound Pressure Level (dB (A))
LPA
β€
55dB (A)
LWA
β€
65 dB (A)
2,6
Global Warming Potential (kg CO2) 2100
EER Class A
Net Weight (Kg) 30 kg
Dimensions W X D X H 386 x 390 x 806 mm
Refrigerant R410A
Applying Space (mΒ²) 20 mΒ²
Miniature Fuse 3,15 A / 250 V ΓΈ5 x L 20 mm
TROUBLESHOOTING
The following cases may not always be a malfunction, please check
suggestions below before asking for service.
Trouble Analysis
Does not run
1. If the protector trip or is blown.
2. Please wait for 3 minutes and start again, protector device may
be preventing unit from working.
3. If batteries in the remote controller are exhausted.
4. If the plug is not properly plugged in
Runs for a short while
only
1. If the set temperature is close to room temperature, you can
lower the set temperature.
2 . Air outlet is blocked by obstacl
e. Take the obstacle away.
Runs but not cooling
1. If the door or window is open
2. If there is another appliance heat-working .like heater or lamp,
etc.
3. The air filter is dirty, please clean it.
4. Air outlet or intake is blocked.
5. Set temperature is too high.
Water leak during
moving
1. Drain the condensate before moving.
2. To avoid water leakage,
Does not run
and water full
indicator"E4"
1. Pull out the rubber pug to drain
water.
2. If it is often in this state, please contact qualified service technical.