38
THEWATERSYSTEM
•Donotusethepumpinwatertemperatures
above40°C(100°F)
•Itisbesttostandthepumpverticallyinthe
tank.
•The micro-switch or phosphor bronze
contactsinthesocketcanberemovedfor
inspectionorreplacement
•The pressure switch is sensitive to drops
in battery voltage. As the voltage falls,
shouldtheunitneedadjustment,turnanti-
clockwise
Tank Drain Operation
Thetankmustbedrainedpriortotravel.
•Locatethe2-wayvalveattachedtotheside
oftheon-boardtank
•Turnthe2-wayvalvetotheopenposition
•Thewaterwilldrainfromthetankbeneath
thecaravan
•Once all the water has been drained turn
the2-wayvalvetotheclosedposition
Routine Maintenance
EnsurethehoseadaptorO-ringandthesocket
inthehousingarekeptfreefromdirt
Useonlysiliconeor water-basedlubricantto
inletnippleO-ringsonsocketforlubrication
Service the inlet socket annually (use Whale
AK8834servicekitcontainingallserviceable
parts)
Draining and Winterisation of the Water
System
Bailey Caravans may be in use all the year
round, but when not in use, even for short
periods, this procedure should be followed.
Onenightinfreezingtemperaturesisallthat
isrequiredforexpensive,permanentdamage
tothewatersystemcomponents.
Ensuring that all water is removed from the
caravans pipework, taps and appliances will
reduce the risk of frost damage occurring.
Frost damage can occur when water left in
thesystemfreezesandexpands,causingthe
pipework and appliances to split, crack or
burst.
•Ideally position the caravan so the drain
valvesareatthelowestpoint,e.g.tiltthe
caravan.
•Switch off the 12v supply for all pumps
at the main control panel (pump isolator
switch)
•Open all taps/mixers in the mid position,
includingtheexternalshower(iftted)
•Removetheshowerhandset(includingthe
external shower if tted) and shake the
waterout
•Open the water heater drain valve and
leaveopen
•Open the on-board tank drain valve (if
present)andleaveopen
•Wheregreywastetanksaretted,remove
allsinkplugsandopenthedraintap
•Openallotherdrainpoints(ifpresent)
•Externalwatercomponents–shakewater
outofpump/Aqua-sourceandstoreinside
thecaravan
•The shower tray cannot be expected to
drainfully,someresidualwatermayremain
whichwillrequire“moppingup
It is essential that the level of ceramic ball
mixer taps is fully raised and in the central
position.Failuretodothiswillnotallowboth
the hot and cold water system to fully drain
andwillresultinfrostdamage.
Frostdamagecannotbeclaimedunder
warranty.
Settingupthewatersystem
•Checkalltheplumbingconnections
•Sterilisethewatercontainerandushthe
systemthroughwithasterilisinguid
•Itisrecommendedthatthewatersystemis