www.balluff.com 19english
6
Calibration procedure (continued)
6.3.3 Online setting
The detailed procedure for online setting is
described on page24.
Setting start and end values while the system is running.
6.3.4 Reset
The detailed procedure for the reset is
described on page25.
Restoring the BTL to its factory settings.
6.4 Selecting the calibration procedure
Fig. 6-6:
1 /
1
+
1 +
1 +
+ 1
a
b
a
b
a
b
a
b
a
b
a
b
a
b
b
a
b
a
Buttons inactive
Reset
Teach-in
Adjusting
Null
point
Null
point
End
point
End
point
Online
setting
Null point
Online
setting
End point
Buttons active
Buttons active
Buttons inactive
Selecting the calibration procedure
BTL7-A/C/E/G5_ _-M_ _ _ _-J-DEXC-TA12
Magnetostrictive Linear Position Sensor – Rod Style
Type of protection “db” and “ta”
Flameproof enclosure