Loading...
Cover
Moved
PanBut.
T
o Fog
Tamper
Reset
Comm.
Tamper output - p. 15
9
Output: Tamper [Tamper]
Tamper
nc nocom
During the normal operation of the connected fog generator
the Tamper output contact between COM and NO is closed.
It switches to COM and NO open and the Tamper LED lights red
from the moment a tamper fault is detected until:
a) There is no Tamper error detected any more, and
b) It has been reset via the Tamper reset button.
As long as a tamper fault (Tamper) remains present, the
front LED of the fog generator will flash red .
Dedetected Tamper errors (sabotage):
a) To Fog:
This red LED lights when a communication error is
detected between the controller and the fog generator.
Possible causes:
None, or poor electrical connection between the three
terminal connectors [Fog] on the controller and the
corresponding three Comm. terminal connectors on the fog generator.
See also p. 20 and set up communication on p. 21.
b) PanBut.:
This red LED lights when a communication error is detected between
the controller and any attached panic button type Bandit 820-xx.
See also input [PanBut] p. 11.
Possible causes:
None, or poor electrical connection between the two
terminal connectors [PanBut.] on the controller and the two
wires from the connected Bandit panic button 820-xx.
c) Cover:
This red LED lights when the fog generator lid (click-on lid above
cartridges) is not properly closed.
BANDIT Controller CF31 v2 / Manual v.102