Input: Panic [PanBut.].
Panic input - p. 9
Through this input a panic alarm generated by the intruder alarm system or
panic button is reported to the BANDIT.
If a panic signal is received on this input the BANDIT will immediately proceed
to Panic mode and commence fog ejection.
However, if the fire mode is active (via Fire-input) or "Fog isolation mode" is
selected there will be no fog ejection.
Features of the Panic mode [Panic]:
- The orange LED [Panic] will be highlighted in the section , Status
as long as the system is in Panic mode“.
- The frontLED of the BANDIT fog generator will flash orange ,
as long as the unit is in Panic -mode“.
Activation of the panic input [PanBut].
In contrast to the four control inputs, this input is not a 12 VDC voltage
controlled input.
This input has two setting modes via dip-switch setting [PanBut.]1
a) NO or NC contact input.
The input monitors whether a connected electrical contact is open
or closed, referenced to terminal block is . +
For example:
- Inside a standard panic button which is normally closed (NC) or normally
open (NO), or
- A serial or parallel connection of several panic buttons or relay contacts.
Settings: See the following page 10.
b) Bandit panic button input.
The input communicates digitally (supply and bus) with an attached BANDIT
panic button of the type: 820-xx.
The panic button is optional and can be ordered from your Bandit dealer.
If the installation requires that the fog generator is directly activated via a
panic button, it is recommended that a BANDIT panic button is used for this
purpose.