Dark SET
SET Button
0.04 seconds < "Click" < 0.8 seconds
Remote Input
0.04 seconds < T < 0.8 seconds
Result
Note: TEACH Selection must be programmed to dr SEt (see Program Mode on page 3 )
Enter Ad-
just Mode
• Set Mode switch to ADJ
No action required; sensor is
ready for Dark SET method
Display: Red - Signal Level;
Green - Threshold
SET Sens-
ing Condi-
tion
• Present sensing condition
• Click the SET rocker but-
ton
• Present sensing condition
• Single-pulse the remote in-
put
T
Threshold Condition Accep-
ted
Displays read "dr SEt" then al-
ternate "PASS" with % Offset*;
Sensor returns to Adjust mode
Threshold Condition Unac-
ceptable
Displays read "dr SEt" then al-
ternate "FAIL" with minimum %
Offset* for sensing condition;
Sensor returns to Adjust mode
Return to
RUN Mode
• Move Mode switch to
RUN
No action required; sensor re-
turns to RUN mode automati-
cally
Display: Red - Signal Level;
Green - Threshold
* See Troubleshooting on page 19 for more explanation of the % Offset displayed after the Dark SET method