Specifications
Sensing Beam
660 nm visible red
Supply Voltage
10 to 30V dc (10% max ripple)
Power and Current Consumption (exclusive of load)
Standard display mode: 960 mW, Current consump-
tion < 40 mA @ 24V dc
ECO display mode: 720 mW, Current consumption <
30 mA @ 24V dc
Supply Protection Circuitry
Protected against reverse polarity, over voltage, and
transient voltages
Delay at Power Up
500 milliseconds max.; outputs do not conduct during
this time
Output Configuration
1 current sourcing (PNP) or 1 current sinking (NPN)
output, depending on model
Output Rating
100 mA max. load (derate 1 mA per °C above 30° C)
OFF-state leakage current: < 5 μA at 30V dc
ON-state saturation voltage: NPN: < 1.5V; PNP: <
2V
Output Protection
Protected against output short-circuit, continuous over-
load, transient over-voltages, and false pulse on power
up
Output Response Time
High Speed - 200 us
Standard - 500 us
Long Range - 2 ms
Extra Long Range - 5 ms
Repeatability
High Speed - 66 us, Standard/Long Range/Extra Long
Range - 100 us
Connections
PVC-jacketed 2 m or 9 m (6.5' or 30') 4-wire integral
cable or integral 4-pin Pico-style QD or Pico-style 150
mm (6") pigtail QD or Euro-style 150 mm (6") pigtail
QD
Indicators
Red 4-digit Display: Signal Level
Green 4-digit Display: Threshold
(In Program Mode, Red and Green displays are used
for programming menus)
Yellow LED: Output conducting
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) hous-
ing, clear polycarbonate cover
Adjustments
3-way RUN/PRG/ADJ Mode Switch
2-way LO/DO Switch
3-way +/SET/- Rocker Button
Expert-style teaching (Two-Point and Dynamic
TEACH, Light/Dark/Window/Calibration SET)
Manually adjust sensitivity (from "+" and "-" rocker
button only)
Response Speed, TEACH Selection, Offset Per-
cent, Auto Thresholds, Delays/Timers, Display
Readout, Gain Selection, Factory Defaults (from
top panel or remote input)
Top panel interface lockout (from remote input on-
ly)
Factory Default Settings:
Setting Factory Default
Threshold 2026
TEACH Selection Two-Point TEACH
Response Speed Standard - 500 us
Offset Percent 10%
Auto Thresholds OFF
OFF Delay 0 (Disabled)
OFF One-Shot 0 (Disabled)
ON Delay 0 (Disabled)
ON One-Shot 0 (Disabled)
Display Readout Numeric, ECO
disabled, Normal
Orientation
Gain Selection Auto Gain
Environmental Rating
IEC IP50, NEMA 1
Operating Conditions
Temperature: -10° to +55° C (+14° to 131° F)
Storage: -20° to +85° C (-4° to +185° F)
Relative Humidity: 90% @ 60° C (non-condensing)
Certifications