93
(g) When the full indicator flashes, the battery capacity is full. The charger has
entered automatically floating state, at the same time, the floating current of the charger is
1-3A.
(h) After having charged, turn off the switch, disconnect the battery plug from the
charger.
(i) Before using the forklift truck, make sure the specific gravity of battery electrolyte
has achieved the value as follows:
Temperature of
electrolyte
Specific gravity of
electrolyte
Temperature of
electrolyte
Specific gravity of
electrolyte
5
1.294
25
1.280
15
1.287
35
1.273
(2) Balanced charging
After the battery fully discharging, measure the specific gravity when charged distilled
water, and that of all batteries, then converse the values (setting the temperature 25),
come out the difference. When the difference is over 0.02, and other performance ruled,
balanced charging is necessary. Charging equally according to these procedures:
After operating by the way the same with daily operating, press “balance” charging
function button, the “balance” indicator flushes and “—JH—” appears. When the battery is
fully charged, press the balance” button to release. The charger returns to normal
condition.
Notice: If charged more frequently, it may lead overcharge and shorten the
useful life of battery.