Service Mode
8-14 5976066 BARCOCINE 7 011299
SOURCE
XX
MEMORY
BANK
4
Select with or
then <ENTER>
<EXIT> to return.
COMMON SETTINGS
G2 ADJUSTMENT
CRT RUN IN CYCLE
PROJECTOR WARM UP
MEMORY BANKS : ON
Select with or
then <ENTER>
<EXIT> to return.
SERVICE MODE
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
MEMORY BANKS
Scroll with or
then <ENTER>
<EXIT> to return.
I2C DIAGNOSTICS
Failures :
addr IC number mod.name
48H IC200 DECODER
How to recall a specific memorybank for the actual source ?
When the memory bank option is ON and a source is selected, this source will be displayed with the last used memory bank settings.
An on-screen menu will give a indication of the memory bank nummer used. To switch to another memory bank :
1. Press ENTER to select the next memory bank in increasing order.
or
2. Enter the number of the desired memory bank with the digit keys.
In both cases, the on-screen indication will be update.
menu 1
menu 2
menu 1 menu 2
I2C Diagnostics
What can be seen ?
The I2C diagnostics menu gives an overview of the I2C failures inside the projector.
To scroll through the failure list, push the the cursor key é or ê .
The I2C address, IC number and module name will be given in I2C diagnostic menu.
When no errors are detected, the following message will appear on the screen :
"No errors on i2c-bus detected".
How to select ?
1. Push the cursor key é or ê to highlight 'I²C Diagnostics' (menu 1).
2. Press ENTER to display the diagnostic menu (menu 2).