32
Replacing Oil
Motor housing - Set unit upright and refi ll with (see chart for type and amount) new cooling oil. Fill to
just above the end bell, (top), of the motor, as an air space must remain in the top of the motor housing
to compensate for oil expansion. Apply pipe thread compound to threads of pipe plug and assemble to
motor housing.
NOTE: Reference oil chart for suitable replacement oils.
SUPPLIER GRADE OUNCES
BP Enerpar SE100 96
Conoco Pale Paraffi n 22 96
Mobile D.T.E. Oil Light 96
G & G Oil Circulating 22 96
Imperial Oil Voltesso-35 96
Shell Canada Transformer-10 96
Texaco Diala-Oil-AX 96
*CONTACT CRANE PUMPS & SYSTEMS FOR A TYPICAL MSDS SHEET IF REQIIRED.
CAUTION: DO NOT OVERFILL OIL. OVERFILLING OF MOTOR HOUSING WITH OIL
CAN CREATE EXCESSIVE AND DANGEROUS HYDRAULIC PRESSURE THAT WILL
DESTROY THE PUMP AND CREATE A HAZARD.
OVERFILLING OIL VOIDS WARRANTY.
Figure
Figure
J
J