Image Acquisition Control
96 Basler ace GigE
For more information about the exposure active output signal, see Section 7.10.1 on page 110.
For more information about the Readout Time Abs parameter, see Section 7.11 on page 123.
Line 1
Line 2
Line 4
Line 3
Line 5
Line 6
Line 8
Line 7
Line 9
Line 10
Line 11
Line N-2
Line N
Line N-1
Readout Time
Exposure Time
= line exposure
= line readout
Frame Start
Triggered
Fig. 45: Global Shutter