Standard Features
232 Basler ace GigE
// Write and read the Device User ID
Camera.DeviceUserID = "custom name";
Pylon::String_t deviceUserID = Camera.DeviceUserID.GetValue();
// Read the Sensor Width parameter
int64_t sensorWidth = Camera.SensorWidth.GetValue();
// Read the Sensor Height parameter
int64_t sensorHeight = Camera.SensorHeight.GetValue();
// Read the Max Width parameter
int64_t maxWidth = Camera.WidthMax.GetValue();
// Read the Max Height parameter
int64_t maxHeight = Camera.HeightMax.GetValue();
You can also use the Basler pylon Viewer application to easily read the parameters and to read or
write the Device User ID.
You can use the Basler pylon IP Configuration tool to read or write the Device User ID.
For more information about the pylon API, the pylon Viewer, and the pylon IP Configuration Tool,
see Section 3 on page 27.