JUNIOR II WT
Page 46 1st ed. Rev 0 Chg 3
BAUER
COMPRESSORS
5.2.2 Maintenance
5.2.2.1 Replacing the Cartridge
See Figure 5-6.
1. Depressurize system before starting any maintenance, by opening the condensate drain valve and
bleed valve.
2. Unscrew plug (5) on top of the housing (4).
3. Extract old cartridge. (2)
4. Dry inside of the housing (4) with a clean cloth. Check for corrosion. Replace if necessary.
5. Lubricate threads, O-rings and threaded portion of replacement cartridge with petrolatum.
6. Insert new cartridge and secure in place with plug (5).
Figure 5-6 P0 Purification System Cross Section
1. Inlet
2. Cartridge
3. Jet Pipe
4. Housing
5. Plug
6. Final Pressure Safety Valve
7. Adjustment Knob
8. Separator Chamber
9. Outlet
10. Pressure Maintaining Valve
11. Bottom
1
11
2
3
4
5
6
7
8
9
10
Cartridge Removal