2. Arrange for the equipment to be connected by an electrician to ensure correct installation of the
electrical wiring.
3. For units which are permanently installed, a main switch must be provided. The main switch must
have a minimum contact gap of 1/8” (3mm) on each pole.
4. Fuse the motor correctly, use slow-blow fuses only.
The label shown in Figure 7-1 indicates the where the incoming power is connected to the compressor
unit’s electrical enclosure. This label must be removed before using the equipment.
7.3 Storage and Preservation
7.3.1 Storage
If the compressor is removed from service for more than six months, the unit should be preserved and
stored in accordance with the following:
Store the unit indoors in a dry, dust-free room.
Only cover the compressor with plastic if it is certain that no condensation will form under the cover.
Even if the unit is kept covered the outside of the unit should be cleaned.
If this procedure cannot be followed or if the compressor is going to be removed from service for
more than two years, please contact our Technical Service Department for special instructions
Table 7-1: Slow Blow Fuse Values
Supply Voltage 110 127 220 230 240 250 380 415 440
3 Phase
Amps 25 25 16 16 16 16 10 10 10
1 Phase
Amps 35 35 20 20 20 20 - - -
Figure 7-1 Incoming Power Wiring Label