Operation manual for BAUER RAINSTAR Series T32, T42 10
Power take-off
1. Drive-shaft protection tube and cone as well as the PTO guard – also on the machine side - must be
mounted and in proper working order!
2. Never connect or disconnect the PTO drive shaft while PTO is running: The engine must be turned off, and the
ignition key pulled out!
3. Attach the safety chain to keep the guard from rotating with the shaft!
4. Before you turn on the PTO make sure that the selected tractor PTO speed corresponds with the permissible
implement speed! Maximum 150 r.p.m.
5. Before starting the PTO make sure that nobody is standing in the danger zone of
the machine!
6. When drive shaft has been removed put the guard on the PTO shaft!
Hydraulic system (RAINSTAR T option)
1. When coupling the hydraulic hoses with the tractor’s hydraulic system make sure that the entire hydraulic
system is pressureless both on the tractor and implement side !
2. Inspect the hydraulic lines at regular intervals and replace them immediately in case of defects or ageing.
Replacement hoses must comply with machine manufacturer’s technical specifications!
3. Liquids emerging under high pressure (hydraulic oil) may penetrate the skin and cause serious injuries! An
injured person must see a doctor immediately! Danger of infection!
4. Always depressurise the system before you work on the hydraulic system !
Maintenance
1. Never service or repair the machine unless the drive is turned off !
2. Dispose of oil, grease and filters according to local laws and regulations!
3. Before electric welding on the RAINSTAR, always uncouple the tractor and disconnect ECOSTAR battery!
4. Spare parts must meet manufacturer’s minimum technical specifications! This is the case with original spare
parts!
Safety distances Z from electric lines at:
IRrigation = ZR e. g.: with drinking water, ground water (e. g. well)
or running water (e.g. stream)
SlurryG = ZG e.g.: with liquid manure or slurry
H = minimum distance between sprinkler upper edge and conductor cable
When crossing beneath an electric line
The safety distance, when crossing an electric line, is reached, if the distances per the below chart are kept. The
water beam may touch the conductor cable, but may not be higher than the conductor cable.