Operation manual for BAUER RAINSTAR Series T32, T42  55 
 
10.  
Electric shut-
off valve 
does not 
close or 
open 
Program constant 
1.  The ECOSTAR is not programmed for a shut-off valve. 
On the parameter sheet no.1.under program constant 6 appears 
setting „2“.  
The constant needs to be corrected to „0“ (with shut-off valve 
overpressure) 
      Furthermore on the parameter sheet no.2 under machine „12“ the 
following value must be entered: 
 
Correct 
adjustments 
 
 
 
 
 
 
      „1“ for both regulating motors  (with shut-off valve) 
Pressure switch 
2.  If a pressure switch for a shut-off when pressure is low is installed the 
reasons could be the following: 
a) Not enough pressure for operating, the pressure is below the value 
which was adjusted at the pressure switch RAINSTAR. 
 
 
 
 
 
Increase 
pressure 
 
b)  Pressure switch dirty or defective. 
In order to check the function of the pressure switch, the pressure 
switch can be put out of operation in the program parameter sheet 
no.2, constant 14, with adjustment „0”. 
Dirt / Foreign bodies / Connections 
3.  The shut-off valve is mechanically blocked by foreign bodies. 
4.  The electronic connections of the shut-off valve are defective or not 
correctly installed. 
Motor for valve (Motor 2) defective  
Clean switch /  
change 
 
 
 
Clean flap 
Check 
connections 
Check motor/ 
change 
11. 
Turbine 
regulation 
does not 
work, valve 
remains 
open or 
closed 
1.  Limiting bolt for the adjustment of the regulating valve is not adjusted 
correctly, valve is closed too much and cannot be opened by the 
motor. (See adjusting table for turbines TVR 60, the adjustment 
depends on the discharge flow) 
2.  
Electronic connections to the motor  (Motor 1) are defective or not 
correctly installed. 
3.  Motor for regulation valve (Motor 1) defective  
4.  Foreign bodies disturb the function of the regulation valve. 
Adjustments of 
the bolt 
according to 
table 
 
Check 
connections/ 
change 
Remove foreign 
body 
12. 
Machine 
stops during 
operation  
1.  If the machine is equipped with a pressure switch, the machine can 
stop if the inlet pressure is too low. 
If the operation of the machine should be continued, the function of 
the pressure switch can be switched off. 
2.  If the required (set) retraction speed is too high and the machine can 
not reach it, for a period of 20min, the machine switches off as well. 
This function, however, can be switched off: 
Machine data, parameter sheet no.1, constant 4 (monitoring of 
correct speed) 
Adjustment e.g „20“ monitoring switched on 
Adjustment „0“   monitoring switched off 
Increase 
connection 
pressure, switch 
off pressure 
switch 
 
 
Reduce 
retraction speed 
 
Switch-off 
monitoring 
13. 
Further open 
questions 
If further problems with the display, accuracy or other functions should 
occur the set data of the  ECOSTAR according to the constants of 
parameter sheet no.1 and the machine data of parameter sheet no.2 