Baumer_ProfibusDPV0_BIDE_MA_EN.docx 11/26 Baumer IVO GmbH & Co. KG
11.19 Villingen-Schwenningen, Germany
Value of parameters of the parameterization function (Set_Prm)
Device
class
Parameter
Data type
Octet
no.
Value range
Default value
In the GSD file
1
Station status
Octet
string
1
Sync and freeze
mode supported
Supported baud
rates
1
Response monitoring time
Octet
string
2 to 3
Profibus-specific data
1
Minimum Station Delay
Responder
Octet
string
4
Baud rate dependent
1
Ident number
Octet
string
5 to 6
059B
1
Group ident no.
Octet
string
7
00
1
Operating parameter
Octet
string
8
Profibus-specific data
1
Operating parameter
Octet
string
9
Bit 0 = 0/1 CW/CCW
Bit 1 = 0/1 Device
class 2 off/on
Bit 3 = 0/1 Scaling
function off/on
CW
Class 2
Device class 2 on
Scaling function on
2
Signal turn resolution
Unsigned
32
10 to 13
Octet 10 is MSB
1 to 1024 magtivo
1 to 8192 multivo
1 to 262144
activo/multivoPlus
1024
8192
262144
2
Total resolution in steps
Unsigned
32
14 to 17
Octet 14 is MSB
1 to 67108864 (2
26
)
magtivo
1 to 536870912 (2
29
)
multivo
1 to 2147483648(2
31
)
activo/multivoPlus
67108864
536870912
2147483648
2
Reserved (system-specific)
18 to 25
0
2
Scaling Speed signal
Octet
string
26
0 to 3
0: steps/s
1: steps/100 ms
2: steps/10 ms
3: RPM
3