Installation
Compact manual b maXX
®
BM4400, BM4600, BM4700
Document no.: 5.06014.02
21
of 94
5
Additional relay is necessary only if the voltage of the brake is 24V, if the current of the
brake is greater than the switching capacity of X101 or if you consider UL508C and the
current of the brake is greater 4 A.
Perhaps consider a limited operating voltage range of the brake because of the internal
voltage drop to max. 2.6 V.
Figure 7: Connection diagram with motor brake controlled via an additional relay.