EasyManua.ls Logo

Baumuller b maxx BM4400 - following_error_time_out Conversion

Baumuller b maxx BM4400
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Application Manual POWERLINK Controlled Node
Document no. 5.13013.04 Baumüller Nürnberg GmbH
62
of 80
following_error_time_out 0x6066/ro PosDevTime
(pos. error time)
P1056 f 0x6066 In the CANopen object and in the
b maXX 4000 controller parameter
the unit is ms.
x = 0 .. 65000 f y = x
position_window 0x6067 f P1194 PPosWindow
(pos. window)
P1194 f 0x6067
x = 0 .. 0xFFFFFFFF f y = x x = 0 .. 0xFFFFFFFF f y = x
position_window_time 0x6068 f P1195 PPosWindow Time
(pos. window time)
P1195 f 0x6068
x = 0 .. 65535 f y = x x = 1 .. 0xFFFF f y = x
velocity_sensor_actual_
value
0x6069 /ro Enc1ActAngle P0391 f 0x6069
x = 0 .. 0xFFFFFFFF f y = x
sensor_selection_code 0x606A /ro - - The b maXX 4000 controller only
supports position encoders, thus
display only.
velocity_actual_value_-
from_position_encoder
x = 0 f y = x
velocity_actual_value_-
from_velocity_encoder
not supported
velocity_demand_value 0x606B /ro SpeedSetValueTotal P0352 f 0x606B The user-defined unit (speed units)
is interpreted in the controller as
rpm.
Only in case if changes in option
module G/H configuration 1
bit 2 = 1: Indication of the current
speed in 1/10 rpm, e.
g.:
200.0
revolutions input 2000.
x = -2
31
.. 2
31
-1 f y = x*Motor-
MaxSpeed /
0x40000000
velocity_actual_value 0x606C /ro SpeedActValue P0353 f 0x606C Only in case of changes in option
module G/H configuration 1
bit 2 = 1: Indication of the current
speed in 1/10 rpm. e.g.:
200.0
revolutions input 2000.
x = -2
31
.. 2
31
-1 f y = x*Motor-
MaxSpeed /
0x40000000
velocity_threshold 0x606F f P1073 Enc1Mon_LLim P1073 f 0x606F The threshold can be raised in the b
maXX 4000 controller up to 25
% of
the maximum speed of the control
-
ler. The input is then effected in rpm
e.g. max: 1000 rpm
input for 25 % = 250 rpm
x = -2
31
.. 2
31
-1 f y = x*0x4000 /
10000
x = -0 .. 0x1000 f y = x*10000 /
0x4000
CANopen object Index
Value range
f P. no.
Scaling
Controller parameters P. no.
Value range
f Index
re-scaling
Comment

Table of Contents