TAM 00695 27
DST2-135 400 W 10 / 2019
Three-phase synchronous motor, water-cooled English
8.7 Min. coolant temperature against ambient temperature and humidity
25% rel. humidity
35% rel. humidity
45% rel. humidity
55% rel. humidity
65% rel. humidity
75% rel. humidity
85% rel. humidity
10
15
20
25
30
35
40
0 5 10 15 20 25 30 35 40
ambient temperature (°C)
min. coolant temperature (°C)
Figure 6: Determination of the coolant temperature
The allowed coolant temperature depends on relative humidity and ambient temperature. For
example with an ambient temperature of 25 °C and a relative humidity of 65 % the minimum
coolant temperature is 18 °C. Because these are limiting values on practical side a coolant
temperature greater than 18 °C should be used.
If this minimum coolant temperature will be under run the two- point controller of Baumüller drive
must be used to avoid condensation (see figure 7 on next page).
Note:
For standstill of motor for longer time the cooling must be stopped.(to avoid condensation).
If ambient temperatures of < 3 °C may occur during a longer motor standstill, coolant should be
discharged as a precaution (to prevent frost damage).