1. Product Information
Technical Data - PGK50 and PGK80
Power supply
Rated power
230 V, 50/60 Hz Optional: 110 / 115 / 120 / 127 / 220 / 240 V
690 VA
PGK50: 1610 VA PGK80: 1380 VA
50 kV DC neg. 80 kV DC neg.
2 mA 0.8 mA
25 mA 20 mA
Installed load
Rated output voltage
Rated output current
Short circuit output current
Accuracy
Timer
Discharge device
±2,5 %
0 - 30 min
for a maximum discharge energy of 1 discharge per 15 minutes,
T
U
=20°C, max. 8000 Ws
Current measuring range
smallest readable current
1 µA / 10 µA / 100 µA / 1 mA / 10 mA / 100 mA
20 nA
PGK50: 0 - 10 kV PGK80: 0 - 16 kV
0 - 50 kV 0 - 80 kV
Voltage measuring range I
II
Relative humidity
Ambient temperature
not condensing
Working: 0°C ... +45°C Storage: - 20°C ... +60°C
Dimensions (WxHxD)
Weight
500 x 285 x 460 mm
25 kg
Conforms to standard
Low voltage directive 73/23/EEC
EN 61010-1, VDE 0104, EMC directive 89/336/EEC with
modification 91/263/EEC, 92/31/EEC; VDE 0843 part 2, IEC 801-2
/ VDE 0843 part 4, IEC 801-4; VDE 0875 part 11, EN 55 011