44
Caution
» LPGlinesmustbeinspectedregularly,atleastannually,andreplacedifanydeteriorati-
on is found.
» If leakage is present, close the cylinder valve and have the system repaired before
furtheruse.Gassystemrepairsshouldonlybeexecutedbyacompetentperson.
» To be able to check the gas connections at the stove the front covers must be removed.
Danger
» Donotsmokeoruseopenamewhilecontrollingforleakages.
» DonotsmokeoruseopenamewhenreplacingLPGcylinders.
» Do not use gas cylinders with damaged threads. Danger of gas leakage.
» Do not use grease or sealants at the valves.
Note: Gas system tightness test
With appliance valves closed!
» Open cylinder valve . close cylinder valve again
» Waituntilthemanometer(inthepressurisedline)hassettledonaconstantreading
» Observe the manometer for 3 minutes
» There is no leak if the pressure reading is constant - should the pressure drop, there is a
leak
Close the valve at the bottle, have the leak repaired - do not use the gas system, before
it has been repaired.
7.12. Gassystemmaindeckgalley
(fornotationssee„7.12.2.Notationofthemaindecksgassystemcomponents“page45)
K
B
A
C
D E
F G
H
L