EasyManua.ls Logo

Baxi Neta-tec Combi GA Range - Information Menu

Baxi Neta-tec Combi GA Range
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
© Baxi Heating UK Ltd 2012
Information Menu
By gaining access to the Information Menu a number of values can be viewed. The information can be used to diagnose
faults, e.g. the value of a sensor to check if it is open circuit or closed circuit
Press ‘ip’ for 1 second.
The display will alternate between the ‘0’i code (e.g. i 02) and its value.
To scroll down the list press the ‘ip’ button.
i 00: Error Subcode See table on page 18
i 01: C.H. Temperature °C
i 02: External Temperature (if present) °C
i 03: D.H.W. Temperature °C i 03 & i 04 are the same sensor
i 04: D.H.W. Temperature °C
i 05: Water Pressure bar
i 06: Return Temperature °C
i 07: Flue Temperature °C
i 08: Heat Exchanger Temperature °C
i 09: Not used
i 10: Not used
i 11: Not used
i 12: Not used
i 13: Not used
i 14: Not used
i 15: Not used
i 16 : Not used
i 17: Fan Speed RPM RPM
i 18: num ic
This function operates for 3 minutes, or can be cancelled by pressing the reset ‘R’ button.
10.0 Information Menu

Other manuals for Baxi Neta-tec Combi GA Range

Related product manuals