Information Menu
By gaining access to the Information Menu a number of values can be viewed. The information can be used to diagnose
faults, e.g. the value of a sensor to check if it is open circuit or closed circuit
Press ‘ip’ for 1 second.
The display will alternate between the ‘0’i code (e.g. i 02) and its value.
To scroll down the list press the ‘ip’ button.
i 00: Error Subcode See table on page 18
i 01: C.H. Temperature °C
i 02: External Temperature (if present) °C
i 03: D.H.W. Temperature °C i 03 & i 04 are the same sensor
i 04: D.H.W. Temperature °C
i 05: Water Pressure bar
i 06: Return Temperature °C
i 07: Flue Temperature °C
i 08: Heat Exchanger Temperature °C
i 09: Not used
i 10: Not used
i 11: Not used
i 12: Not used
i 13: Not used
i 14: Not used
i 15: Not used
i 16 : Not used
i 17: Fan Speed RPM RPM
i 18: num ic
This function operates for 3 minutes, or can be cancelled by pressing the reset ‘R’ button.
10.0 Information Menu

Other manuals for Baxi Neta-tec Combi GA Range

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi Neta-tec Combi GA Range and is the answer not in the manual?

Baxi Neta-tec Combi GA Range Specifications

General IconGeneral
BrandBaxi
ModelNeta-tec Combi GA Range
CategoryBoiler
LanguageEnglish

Related product manuals