7. MENU SET
Press and hold before turning the scale on. The UNIT WEIGHT screen shows the information and the WEIGHT
screen shows the value. After all the set is over, it will automatically back out from the menu set and back to the wei-
ghing and counting mode. Press
for change the value and press for go to next menu.
Specific set as follows:
Nº de serie Pantalla
Valor progra-
ma
Programa de introducción
1
Zero
Zero tracing
0d
0 stands fro no tracing.
1 stands for tracing 1d
The bigger tracing vlue, the quicker back to zero
1d
2d
3d
2
Zrage
Zero range
0d
Quand plus grand est la valeur programmée, plus
rapidement retournera à zéro.
1d
2d
3d
3
D-rng
Dynamatic examination
0d
The bigger dynamic value is, the more stable is. But
the resolution is worse and it’s suitable to be used
in a worse enviroment.
1d
2d
3d
4
Pass
Warning internal and
external limit
0 0 stands for the warning internal limit presetting
1 1 stands for the warning external limit presetting
5
Point
Average filter
4
The bigger the filter point is, the more stable the
scale is. But the reaction speed is lower.
8
16
6
Spnt
Calibration mode
0 Multipoints calibration not allowed
1 Multipoints calibration mode allowed
7
Speed
Sample speed
0 Factory set
1 Fast sampling
8
Filt
filter
0
1
2
3
9
Aver
Auto-averaging
0 Allow auto-averaging
1 Forbid auto-averaging
10
A-Salt
Alarm
0 For counting
1 For weighing
11
OLoad
Zero memory
0 Zero desviation correction
1 No zero desviation correction (zero memory ON)