Troubleshooting
Fault Possible cause Remedy
The motor does not start after
pressing the ON/OFF switch
or stops during operation.
Plug not inserted into socket. Insert plug.
Automatic circuit breaker
tripped.
Switch on the automatic circuit
breaker again.
The magnetic clamp is not
switched on.
Switch on the magnetic clamp.
The automatic circuit breaker
in the electrical distribution
board trips.
Too many appliances con
-
nected to the same power
circuit.
Reduce the number of appli-
ances on the power circuit.
The machine is defective. Contact customer service.
The magnetic clamp does not
function.
Magnet not switched on. Switch on the magnet.
The surface is not magnetic. Use a suitable base.
The lubrication system does
not function.
No lubricant available. Top up the lubricant.
Lubricant tap closed. Open the lubricant tap.
Connecting nipple clogged. Clean the tank and nipple.
NOTE
If you cannot resolve the problem with the steps described above, please contact cus
-
tomer service.