R
Rhonda SmithSep 12, 2025
What happens if BEA Security Sensors door moved manually during closed door tracking?
- MmurilloerinSep 13, 2025
If the BEA Security Sensors door moved manually during closed door tracking, perform an Automatic Recovery.
What happens if BEA Security Sensors door moved manually during closed door tracking?
If the BEA Security Sensors door moved manually during closed door tracking, perform an Automatic Recovery.
Why is the BEA LZR-MICROSCAN T hub LCD not on?
If the LCD on your BEA Security Sensors hub is not turning on, there could be a few reasons. First, verify the power supply connection to ensure it's properly connected. If the connection is good, check the power supply itself, ensuring it's a BEA power supply. If both of these are fine, the hub might be faulty and may require replacement.
What to do if BEA LZR-MICROSCAN T Security Sensors door(s) keep recycling (ghosting)?
If your BEA Security Sensors door(s) keep recycling or 'ghosting', it could be due to the approach-side sensors detecting motion. Try adjusting the Activation Distance and/or motion sensor settings of the approach-side sensors. Another cause might be the Home Switch not properly registering when the door is closed. In this case, adjust the Home Switch and check its wiring.
What does orange flashing LED on BEA Security Sensors mean?
An orange flashing LED on your BEA Security Sensor indicates an error. Possible causes include: * The sensor is mounted too high or adjusted too close to the door. * The door did not fully open during the learning phase (EDPS). * The number of doors configured is incorrect (BUS config). * The sensor is obstructed by an object (boundary). * There is a loose or broken sensor harness (lost message).
What does it mean if BEA LZR-MICROSCAN T Security Sensors signal an internal fault?
If the BEA Security Sensor signals an internal fault, cycle the power. If the orange LED flashes again, replace the sensor.
What does it mean if BEA Security Sensors signal an external fault?
If the BEA Security Sensor signals an external fault related to power supply or temperature environment, install a BEA power supply and verify the temperature.
How to fix 'Height/Angle Error' on BEA LZR-MICROSCAN T Security Sensors?
To address a 'Height/Angle Error: No floor recognized' issue with BEA Security Sensors, check the mounting height and angle against the template. If a transfer loop is present, ensure it is trimmed and not hanging under the sensor. Also, verify the sensors are handed correctly for the mounting location (i.e. Left Mount / Right Mount). If the sensor is detecting door hardware, tighten the tilt adjustment screw and install LZR spacers if necessary.
What to do if BEA LZR-MICROSCAN T Security Sensors do not show “CLEAR AREA” during setup?
If the BEA Security Sensors do not show “CLEAR AREA” during setup, verify the sensor harness connection.
How to fix Hub Environment error in BEA LZR-MICROSCAN T Security Sensors?
To resolve a Hub Environment error on BEA Security Sensors, verify the power supply voltage and ensure you are using a BEA power supply. Also, ensure that the environment temperature is within the operational range for the hub.
What to do if BEA Security Sensors door(s) will not open/ close?
If the BEA Security Sensors door(s) will not open or close, verify that the door control is operational without any wiring. Also, ensure all connections are secure, including sensors and the On/Off/Hold Open switch. Check if the Knowing Act is turned on and either turn it off or use Knowing Act devices. Verify the wiring from the hub to the door control and confirm monitoring settings and wiring are correct.