75.5961.05 IXIO FAMILY QG 20230410 Page 1 of 4
IXIO FAMILY
! !
1
Activation and safety sensors
for automatic sliding doors
ENGLISH
READ BEFORE BEGINNING INSTALLATION & SETUP
Refer to the User’s Guide
for full instructions.
This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in
exact accordance with the instructions provided with this kit. Operation is subject to the following
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Only trained and
qualified personnel
are recommended for
installation and setup of the
sensor.
The warranty is invalid if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Following installation,
always test for proper
operation (according to
ANSI 156.10) before leaving
the premises.
The door control unit
and the header cover
profile must be correctly
grounded.
max. 2 in
CAMERA HARNESS FOR DT1 V
RED
SENSOR
DOOR CONTROL
BLACK
BROWN
BLUE
WHITE (COM)
YELLOW (N.C)
GREEN (N.O.)
PURPLE
PURPLE
POWER SUPPLY
POWER SUPPLY
SAFETY INPUT
SAFETY INPUT
TEST OUTPUT*
TEST OUTPUT*
OPENING INPUT
OPENING INPUT
OPENING INPUT
The sensor should be
mounted securely to
avoid extreme vibrations.
Avoid highly reflective
objects in the infrared
field.
Avoid moving objects
and light sources in the
detection field.
Do not cover the sensor.
MOUNTING & WIRING
Sensor connectivity (power and relays) must utilize only
the supplied harness.
Sensor power must be supplied from a Class 2 supply
source limited to 15 W.
Sensor is intended to be monitored for proper
operation by the door operator or system.
Harness shall be routed separated from any Mains or
non-Class 2 voltage cable for correct operation or shall
be rated for the Mains voltage, and suitable protection
and routing means shall be used according to National
and Local Codes to prevent damage to the harness
and/or IXIO sensor.
RCA VIDEO OUT ♀
POWER
(12 – 24 VAC/VDC)
Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application.
QUICK GUIDE
POWER
12 – 24 VAC/VDC
12 – 30 VDC
2.5 W (max)
TEST
low: < 1 V
high: > 10 V (30 V max.)
response time: typ. < 5 ms