P. [Unit] Setting
range
Description Ex works
760
0..18
Function Rel1 (BDC-XXX M2)
Selection of the output function for output Rel1
This parameter can only be set when P.801:1.
0
770
0..18
Function Rel2 (BDC-XXX M2)
Selection of the output function for output Rel2
This parameter can only be set when P.801:1.
0
780
0..18
Function Rel3 (BDC-XXX M2)
Selection of the output function for output Rel3
This parameter can only be set when P.801:1.
0
790
0..18
Function Rel4 (BDC-XXX M2)
Selection of the output function for output Rel4
This parameter can only be set when P.801:1.
0
800
0..1
Activation extension board BDC-XXX M1
The extension board is activated using this parameter.
0: Inactive
1: Active
0
801
0..1
Activation of the extension board
The extension board is activated using this parameter.
0: Inactive
1: BDC-XXX M2
2: NFC module
0
802
0..1
Activation radio receiver parameters
0: Inactive
1: Active
0
803
0..1
Activation of the parameters for the safety radio receiver RB3 CSM868AD1
0: Inactive
1: Active
0
892
0..1
Parameter approval stop light
0: Inactive
1: Activation of parameters for two-way traffic control.
0
910
0..3
Selection display mode diagnostics 1
Using this parameter, the measurements below can be shown directly on the door
control unit display.
0: The control sequence is displayed (automatic)
1: The running time of the motor in seconds during the last door movement
2: The current position in %
3: The current position in increments
0
920
0..20
Error history
The control unit saves the last 20 errors to occur in the error memory. After jump-
ing to parameter P.920, the errors which have occurred can be displayed by turn-
ing the DDT(L), (R). In roll mode, the display alternates between showing the
stroke during which the error occurred and the error itself after approx. 5 seconds.
After the errors, "end" appears on the display.
If noEr appears on the display, this means that no error has been recorded.
0
925 Software version
In this parameter, the version of the current software in use is displayed.
45

Table of Contents