EasyManua.ls Logo

Bego Nautilus T - Automatic Casting: Melting Process Steps

Default Icon
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
86105 BA-en/00
English Nautilus
®
CC plus
en
9. Confirm the melting process by pressing the
"OK" button or skip it by pressing the "Abort"
button.
The actual temperature as well as the casting
temperature are automatically displayed as
soon as the casting temperature has been
reached. With crucible inserts, the display will
not appear until the "Holding time" has elapsed
to ensure that the melt is thoroughly heated.
The subsequent process is carried out auto-
matically; however, manual interventions are
possible (see next step).
The casting process will be triggered automati-
cally once the proper casting temperature has
been reached. Manual interventions are possi-
ble, as needed:
10. The casting process can be triggered manually
by pressing the "Casting" button any time after
the alloy has been melted.
The casting is carried out with overpressure.
Alloy, chamber pressure, casting temperature
and casting number will be displayed during
that process.
WARNING
Never look into the melt without
protective glass and protective
eyewear!
CAUTION
The casting process may fail when
triggered manually!

Other manuals for Bego Nautilus T

Related product manuals