MIDI SysEx Messages
The following data format is used when creating a SysEx message, and the various items in this SysEx data string are described below:
Frame start
F0
Manu ID
00 2032
Device ID
aa bb cc
PKT
dd
SPKT
ee
Parameter
D0 … Dn-1
Frame end
F7
Item (Hex) Description
00 20 32 Manufacturer SysEX ID number (Behringer GmbH)
aa bb cc Device ID: 00 01 20 for MS-1
dd It is a main packet type (abbr. PKT).
ee It is a sub packet type (abbr. SPKT). SPKT is absent for some packets.
D0 … Dn-1 Parameter value.