EasyManua.ls Logo

BenchMark Wireline AM5K Series - Magnetic Mark Detector Specification

BenchMark Wireline AM5K Series
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
benchmarkwireline.com
P. O. BOX 850
Fax: 281.342.4848
Phone: 281.342.6415
Simonton,Texas 77476
36220 FM 1093
AM5K User Manual Rev Q Oct 2007 Page 30 of 44
6.2 MAGNETIC MARK DETECTOR SPECIFICATION
1. General
This specification describes the latest magnetic mark detector. It replaces the
original AMS100 detector, p/n AMS1A003. The performance characteristics
emulate the original unit.
2. Mechanical
The mark detector will work in both the original housing p/n AMS1M022 and the
AM5K versions using p/n AM5KM029. The pc board is potted to prevent
damage from shock, vibration, or humidity.
3. Power
Input power is 9 - 30vdc at 100ma max.
4. Outputs
Digital line driver out for strong & strong\ and also weak & weak\ where a weak
mark is 4 gauss or less and a strong mark is greater than 4.1 gauss measured
0.10 inch from cable surface. The signals are a +5vdc digital pulse. A digitized
0-5vdc representation of the analog signal is provided.
5. Performance
a) Operating temperature -40 to +120 f. compensated and stable. Storage
temperature -60 to +180 f.
b) Magnetic mark detection at cable line speeds of 1 to 1000 feet per minute.
c) Auto cal feature removes offset of the electronics and any constant
magnetic field less than 1 gauss every 100ms. If in a greater field, it will
auto calibrate every 11 seconds.
d) Detection of apparent zero gauss (at high/low crossing) is within 0.1 inch
and repeatable so as any error is not accumulative.
e) Will survive a gauss level exposure of 60 gauss.