7
2.3 CONTROL FUNCTIONS
AC Circuit Breakers
While the generator is running, the breakers should be put in the ON
position.
If the current has exceeded its limits it will automatically pop out to the
OFF position. Reduce the electrical load on the generator and push the
button back to the ON position.
DC Circuit Breakers
The DC circuit breaker automatically shuts off when the charging circuit
is overloaded.
If the current has exceeded its limits the breaker will automatically pop
out to the OFF position. Reduce the electrical load on the generator and
push the button back to the ON position.
Hour Meter
Display shows total run time. Use this to perform maintenance at the
proper intervals according to the ‘Maintenance Schedule’ section of this
manual.
EcoMode (Economy Control Switch)
Turning EcoMode to ON is recommended for minimizing fuel
consumption. In this mode the engine will dynamically meet the demand
of the current electrical load and will automatically go into an idle state if
all electrical loads are disconnected.
Before connecting or removing a high load device to the generator, turn
EcoMode to OFF until that device has reached running power.
When EcoMode is OFF, the engine runs at full speed.
Ground Terminal
WARNING!
Before using the ground terminal consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local
laws and codes that apply to the intended use of the generator.
The ground terminal is connected to the non-current carrying metal
parts (such as the fuel tank), the frame, and the ground terminals of the
AC outlets. Floating Neutral.