22
7.2 CHANGING THE OIL
WARNING!
Used motor oil can cause skin irritations if left in long-term
contact with skin. Thoroughly wash off used oil from hands as
soon as possible with soap and water.
Do not dispose of used oil in drains or on soil. Local service
shops provide environmentally-friendly disposal methods.
Remove the spark plug boot from the spark plug before
performing maintenance procedures on the generator to avoid an
accidental start-up.
Drain the oil rapidly and completely while the engine is still warm.
1. Place an oil collection pan under the oil drain bolt. Loosen the oil drain bolt
then tip the generator and continue to fully loosen the bolt.
2. Drain into the oil collection pan completely. Reinstall the oil drain bolt.
3. Rell the oil to the maximum level mark. Check the oil level by reinserting
the dipstick without rethreading it. Remove the dipstick and examine the oil
level when the unit is on a at surface.
4. Reinstall the oil dipstick and tighten it.
NOTE
Max oil capacity: 20 . oz / 0.6L
SAE 10W-30 or Synthetic 5W-30 oil is recommended for general use.
Use of synthetic oil does not change maintenance intervals.
DO NOT OVERFILL.
Ready to Use
Pret a utiliser
Low Oil
Huile bas
Overload
Surcharge
1 2 3 4
1 32
1
2 3
STOP
CLOSED
OFF
ON
BG i-SERIES