5. GENERATOR USE
WARNING!
Before using the generator, consult a local electrician and local
electrical codes to determine grounding requirements for your
intended use. This generator is floating neutral.
Do not connect to the building’s electrical system. Doing so may
result in electrical shocks and fire.
To prolong engine life, do not exceed the rated running wattage.
Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a tough
rubber sheathed flexible cable (according to IEC245 or equivalent
standards). The maximum length of the extension cable: 196
feet (60 meters) for cable of 15.5 gauge
(1.5mm
2
); 328 feet (100
meters) for cable of 13.25 gauge (2.5mm
2
).
Keep away from other electric cables or wires.
5.1 READY TO USE, OVERLOAD, AND OIL ALERT INDICATOR
Light (Solid) Description
Green Ready to Use Indicator ON Indicates normal operation
OFF Indicates a problem or unit is off
Red Overload Indicator ON Indicates overload or problem with
connected appliances, disconnect any
appliances.
OFF Indicates normal operation
Red Low Oil Indicator ON Indicates insufcient oil in the
crankcase
OFF Indicates normal operation
Ready to Use
Pret a utiliser
Low Oil
Huile bas
Overload
Surcharge