LUBRICATION
1. After installation and start up as been
completed, lubricate lift components as
described below. ( See Fig. 26 )
START-UP AND BLEEDING
1. After electrical power is connected and oil
reservoir is full press button to raise lift. Cylinders
may “jump” upon initial start up which is normal.
2. Continue raising until lift cylinders bottom out
at full height. DO NOT continue pressing button
after lift reaches full height. Damage to motor
can occur if continued.
3. Lower the lift only HALF WAY by pressing the
SAFETY RELEASE handle inward then pressing
in the DOWN lever on power unit.
4. With the lift at half height, slowly loosen the
BLEED SCREWS located at the top of each cylin-
der (Fig 27) to bleed trapped air. DO NOT com-
pletely remove bleed screws. Retighten after
trapped air has escaped.
5. Lower the lift completely by pressing the
SAFETY RELEASE handle inward then pressing
the DOWN lever on power unit and repeat bleed-
ing process one additional time.
BE AWARE!
During the START-UP procedure, observe all
operating components and check for proper
installation and adjustment. DO NOT attempt to
raise vehicle until a thorough operational check
has been completed.
RISK OF EXPLOSION!! This equipment has
internal arcing or sparking parts which
should not be exposed to flammable
vapors.