40
111660 Rev C 5-13-14
How to Program the Dispenser for Operation
Dresser
loop
Option 2
COdE
21
How To Set The Dispenser Communication Type
Menu Code 21
 0 - Bennett Current Loop (Bennett 515 Controller to Verifone or TMS MPC)
 1 - Stand Alone
 2 - Dresser Wayne Loop ( Bennett 621 Controller to POS supporting Wayne Fuel Protocol )
 3 - Bennett RS485 Retail ( Allied NexGen or POS supporting Bennett RS485 Retail)
Stand
alone
COdE
21
Option 1
current
Loop
Option 0
To select a different option in Menu Code 21, follow this
procedure:
1. After the Manager’s Mode has been accessed, press
the number 2 and 1, then the MODE button on the
keypad. The price display shows the dispenser is in
Menu Code 21.
If the dispenser has not been programmed since it
came from the factory, the default setting is 0 for
Current Loop.
2. To change the setting, use the 0 - 3 buttons on the
keypad to enter a new option.
NOTE: If an error is made, press the correct number.
The new number replaces the error.
3. When the correct option number appears in the main
display, press the ENTER button to save the selection
4. Press the CANCEL button to exit this menu code.
5. If initial programming of a dispenser with two fueling
positions is being performed, program the other side.
COdE
21
Rs485
Option 3
COdE
21