Critical safety warnings regarding fire, explosion, injury, and death.
Precautions for safe operation, installation, and handling of equipment.
Explains how dispenser model numbers are constructed based on features.
Details how dispenser identification numbers are coded for standard flow models.
Details how dispenser identification numbers are coded for high flow models.
Step-by-step guide for safely unpacking and inspecting delivered dispensers.
Steps to safely remove the dispenser from its pallet and lift it using straps.
Instructions for gently placing the dispenser onto the concrete island.
Describes the alternate lifting method for high hose dispenser models.
Details the process of bolting the dispenser to the island and using shims for leveling.
Guidelines for dispenser mounting on concrete foundations and using containment sumps.
Guidance on finding and following specific wiring diagrams for dispenser models.
Critical warning about not crossing phases to prevent damage.
Steps for purging air from product lines in remote dispenser systems.
Steps for purging air from product lines in self-contained dispenser systems.
How to connect AC power to the dispenser, including circuit breaker rules.
Setting JP1-5 to configure the dispenser for Console or Stand Alone operation.
How the dispenser authorizes itself without an external signal in Stand Alone mode.
Using jumpers 1-4 on JP1 to set the fueling point address for the dispenser.
Detailed procedure for electronically calibrating the SB-100 meter via the CPU/Display board.
Entering test can size and measured error for electronic calibration.
Final steps to complete and seal the electronic calibration process.
Instructions for routing field wires through conduit into the dispenser enclosure.
Critical steps for establishing a safe and compliant earth ground connection.
Connecting AC power to remote dispensers, including circuit breaker rules.
Performing essential checks before applying AC power to prevent damage.
Specific startup steps for self-contained pump dispensers.
Procedures for checking remote pump motor circuits and verifying voltage.
Step-by-step guide for mechanically calibrating the SB-100 meter using the calibration wheel.
Standard procedure for electronic calibration using cubic inch or CC measurements.
Procedure to directly enter or overwrite the electronic calibration constant.
Procedure for electronic calibration using percentage measurements.
A comprehensive checklist to verify proper installation and setup.
Details warranty service procedures, authorized representatives, and installation requirements.
Outlines warranty service procedures for international installations.