Appendix D - EU Declaration of Conformity
117
Appendix D - EU Declaration of Conformity
EU Declaration of Conformity
According to the EMC Directive 89/336/EEC, as Amended by 92/31/EEC and 93/68/EEC.
Product
Category
Motor Controller
Product Type Reduced Voltage Solid State Motor Controller
Model Numbers MX2SEP-125VDC-025A-1-S-C MX2SEP-250VDC-025A-1-S-C
MX2SEP-125VDC-050A-1-S-C MX2SEP-250VDC-050A-1-S-C
MX2SEP-125VDC-100A-1-S-C MX2SEP-250VDC-100A-1-S-C
MX2SEP-125VDC-200A-1-S-C MX2SEP-250VDC-200A-1-S-C
MX2SEP-125VDC-400A-1-S-C MX2SEP-250VDC-400A-1-S-C
MX2SEP-125VDC-600A-1-S-C MX2SEP-250VDC-600A-1-S-C
Manufacturer's
Name
Benshaw, Inc.
Manufacturer's
Address
615 Alpha Drive
Pittsburgh, PA 15238
United States of America
The before mentioned products comply with the following EU directives and Standards:
Safety UL 508 Standard for Industrial Control Equipment covering devices for starting, stopping, regulating, controlling,
or protecting electric motors with ratings of 1500 volts or less.
Electromagnetic
Compatibility
• EN 50081-2 Emissions Radiated/Conducted
• EN 55011/05.98+A1:1999
• EN 50082-2 Immunity/Susceptibility which includes:
• EN 61000-4-2 Electrostatic Discharge
• EN 61000-4-3 Radiated RF
• EN 61000-4-4 Electrical Fast Transient/Burst
EN 61000-4-6 Injected Currents
The products referenced above are for the use of control of the speed of AC motors. The use in residential and
commercial premises (Class B) requires an optional EMC series filter. Via internal mechanisms and Quality
Control, it is verified that these products conform to the requirements of the Directive and applicable standards.
Pittsburgh, PA USA - 1 January 2008
Neil Abrams
Quality Control Manager

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BENSHAW RediStart MX 2 SEP Series and is the answer not in the manual?

BENSHAW RediStart MX 2 SEP Series Specifications

General IconGeneral
CategoryController
Frequency Range50/60 Hz
Operating Temperature-10°C to 50°C
Protection FeaturesOverload, short circuit, phase loss, under voltage, over voltage
Communication OptionsEthernet
Enclosure RatingNEMA 1
Humidity5-95% non-condensing
AltitudeUp to 1000 meters without derating
SeriesRediStart MX 2 SEP Series