7 Bentone
General
Control system 10 years 250,000 starts
Valve control system 10 years 250,000 starts
Pressure switch 10 years 250,000 starts
Ignition system with flame guard 10 years 250,000 starts
UV flame sensor 10000 hrs N/A
Gas pressure regulators 15 years N/A
Gas valve without seal testing 10 years 250,000 starts
Gas valve with seal testing Replacement upon fault detection N/A
Gas pressure switch 10 years 250,000 starts
Safety blow-off system 10 years N/A
Damper motor N/A 500,000 starts
Contactor 10 years 500,000 starts
Burner 1 year 3000 hrs
Inspection of electrical installation 1 year 3000 hrs
Leakage check 1 year 3000 hrs
Filter 1 year replacement at ∆p>10 mbar 3000 hrs replacement at ∆p>10
mbar
Electrodes Replacement/Cleaning 1 year Replacement/Cleaning 3000 hrs
Brake disc Replacement/Cleaning 1 year Replacement/Cleaning 3000 hrs
Motor 1 year 3000 hrs
Fan wheel 1 Year
Replacement when cleaning
needed/ imbalance
3000 h
Replacement when cleaning
needed/ imbalance
The burner and its components must be recycled according to applicable regulations.
Burner servicing schedule
Servicing must be carried out once a year or after 3000 hours of operation
Component replacement intervals
Delivery check
• Make sure everything is delivered and the goods have not been
damaged during transit.
• If something is wrong with a delivery, report it to the supplier.
• Transport damage must be reported to the shipping company.