Turn the power and gas feeding to the boiler back on.
Replacing the burner insulating panel
Unscrew the ignition/detection electrode fixing screws and remove it.
Remove the burner insulating panel (A) by inserting a blade underneath
the surface (as shown in the figure).
Remove any fixing glue residue.
Replace the insulating panel.
The new insulating panel does not need to be fixed in place with glue as
its geometry ensures perfect coupling with the heat exchanger flange.
Reassemble the ignition / detection electrode using the previously
removed screws and replacing the relative seal.
A
B
C
A
4.1 Programmable parameters
A list of the programmable parameters is given below: USER (level always available) and INSTALLER (access with password 18);
for a detailed
explanationoftheparameters,refertoparagraph“4.2 Parameters description”
.
b
Someinformationmightnotbeavailabledependingontheaccesslevel,machinestatusorsystemconguration.
Parameters
Value
Password
level
Value set in
the factory
Personalised
values
min max
CONFIGURATION
301 HYDRAULIC CONFIG. 0 4 INSTALLER 2
306 MIN FAN SPEED 1.200 3.600 INSTALLER
see technical data table
307 MAX FAN SPEED 3.700 9.999 INSTALLER
see technical data table
308 SLOW IGNITION ADJUSTMENT MIN MAX INSTALLER
see technical data table
309 MAX CH FAN SPEED MIN MAX INSTALLER
see technical data table
310 RANGE RATED MIN MAX_CH INSTALLER
see technical data table
311 AUX OUTPUT 0 2 INSTALLER 0
312 FLUE GAS COUNTER RESET 0 1 INSTALLER 0
HEATING
405 SET PUMP NOT APPLICABLE ON THIS MODEL
408 OT+ CASCADE NOT APPLICABLE ON THIS MODEL
409 SCREED HEATER 0 1
INSTALLER
if boiler in OFF
and LT systems
0
410 HEATING OFF 0 min 20 min INSTALLER 3 min
411 RESET HEATING TIMES 0 1 INSTALLER 0
415 MAIN LT ZONE 0 1 INSTALLER 0
416 MAX TEMP (MAIN ZONE) MIN TEMP (MAIN ZONE) HT: 80.5 - LT: 45.0 INSTALLER HT: 80.5 - LT: 45.0
417 MIN TEMP (MAIN ZONE) 20
MAX TEMP (MAIN ZONE)
INSTALLER HT: 40 - LT: 20
418 THERMOREGULATION (MAIN ZONE) 0 1
INSTALLER
if ext. probe present
0
419 CURVE SLOPE (MAIN ZONE) HT: 1.0 - LT: 0.2 HT: 3.0 - LT: 0.8
INSTALLER
only if 418 = 1
HT: 2.0 - LT: 0.4
420 NIGHT-TIME COMP. (MAIN ZONE) 0 1 0
432 BUILDING TYPE 5 min 20 min 5 min
433 EXTERNAL PROBE REACTIVITY 0 255 20
DHW 0
508 MIN DHW TEMP. 37.5 °C 49.0 °C INSTALLER 37.5°C
509 MAX DHW TEMP. 49.0 °C 60.0 °C INSTALLER 60.0°C
511 SPEC. DHW FUNCTIONS 0 5 INSTALLER 0
USER PARAMETERS
INSTALLER PARAMETERS
Parameters
Value
Password
level
Value set in
the factory
Personalised
values
min max
SETTINGS
004 MEASUREMENT UNIT 0 1
USER
0
006 BUZZER 0 1
USER
1
Cleaning th siphon
Remove the siphon as described below:
Switch off the electrical supply by turning the system’s main switch to “Off.
Disconnect the degassing pipe (see figure below)
Disconnect the condensate drain pipe coming from the exchanger (see
figure below).
Remove the clip securing the siphon to its manifold (see figure below).
Remove the siphon from its seat.
Wash the siphon by circulating water from the connection with the
hose nozzle. IN NO CASE USE METAL OR POINTED TOOLS TO
REMOVE DEPOSITS OR RESIDUES INSIDE AS THEY COULD
DAMAGE ITS COMPONENTS.
b
Do not remove the safety shutter and its sealing gasket as their
presence is intended to prevent the escape of burnt gases into the
environment in the event of no condensation.
Oncetheoperationshavebeencompleted,reassemblethecomponents
byoperatinginthereverseordertowhatisdescribed,checkingthecorrect
positioningandintegrityofthesealingOR,andreplaceitifnecessary.
b
Attheendofthecleaningsequence,fillthesiphonwithwater(see
paragraph ”3.2 First commessioning”) before starting the boiler again.
b
Attheendofthesiphonmaintenanceoperations,itisrecommended
to bring the boiler to condensing mode for a few minutes and to check
for leaks from the entire condensate evacuation line.