ENGLISH
- remove the two screws
B
- push the casing
C
forwards
- move the casing
C
upwards, freeing it from the top hooks
Models 11-13 Models 17
B
C
C
B
Fig. 44
Models 11-13
Toaccesstheinstrumentpanelremovethexingscrew
D
and turn it
D
Fig. 45
Models 17
To open the instrument panel:
- remove the screws
C
- slide the instrument panel out and rotate it to the stop position
D
Fig. 46
At the end of the operations described above, put everything back in the
reverse order.
b
The gasket
F
should always be in its original seat.
F
Fig. 47
6.3 Accessing the modulation circuit board
b
First disconnect the appliance from the electrical power supply us-
ing the mains omnipolar switch.
Models 1
1-13
- To access the electronics of the control box, remove the casing and
turn the instrument panel
- Remove the cover to access the board.
Fig. 48
Models 17
- To access the electronics of the control box, remove the casing and
take out the instrument panel
- remove the two screws
G
- remove the cover and access the board.
G
Fig. 49

Table of Contents

Other manuals for Beretta IDRABAGNO Lx 13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beretta IDRABAGNO Lx 13 and is the answer not in the manual?

Beretta IDRABAGNO Lx 13 Specifications

General IconGeneral
BrandBeretta
ModelIDRABAGNO Lx 13
CategoryBoiler
LanguageEnglish

Related product manuals