3.3.3.2 Vacuum time setting (sensor disabled):
For a selected program set the vacuum time, in seconds; the validation is
automatically performed following the second digit entry (the new vacuum time is
blinking). In a middle
of
an acquisition, use key "ENTER" to validate the vacuum
time and key "ESC" to come backward and start over with a new acquisition (the
old vacuum time is blinking).
Examples: 1 s
keys 0, 1 or
1,
ENTER
15s
keys 1, 5
3.3.3.3 Vacuum level setting (sensor enabled)
For a selected program set the vacuum level, starting with the values; the
decimal point is automatically inserted following the second digit entry and the
validation is automatically performed following the third digit entry (the new
vacuum level is blinking). The vacuum level is rounded
off
to the nearest half
value. In the middle
of
an acquisition, use key "ENTER" to validate the vacuum
level and key "ESC" to come backward and start over with a new acquisition
(the old vacuum level is blinking).
Set
vacuum level to zero to bypass
the
pressure transducer
and
proceed only using the vacuum plus time.
Examples: 90.0%
keys
9, 0, 0
or
9, 0, ENTER
or
keys 9, 0, 1 or 9, 0, 2
or
9, 0, 3
or
9,
0,
4
97.5%
keys
9, 7, 5 or
keys 9, 7, 6
or
9, 0, 7
or
9, 0, 8
or
9,
0, 9
0.0%
keys
0, 0, 0 or 0, ENTER
3.3.3.4 Vacuum plus time setting (sensor enabled)
For a selected program set the vacuum plus time, in seconds; the validation is
automatically performed following the second digit entry (the new vacuum plus
time is blinking). In a middle
of
an acquisition, use key "ENTER" to validate the
vacuum plus time and key "ESC" to come backward and start over with a new
acquisition (the old vacuum plus time is blinking).
Examples: 1 s
keys
0,
1
or
1,
ENTER
15s
keys
1,
5
3.3.3.5 Gas time setting (sensor disabled)
For a selected program set the gas time se~ing following the same procedure as
11