LaserSpeed 8000/9000 I/O Module Instruction Handbook
Installation
Part No. 93342 / Drawing No. 0921-01516 Page 23 of 84 Revision E (Dec 2013)
Example: If data is required every 2 ms, the PLC should pulse the Data Request
signal every 2ms. The Data Ready Pulse Width should be configured to be less
than half the Data Request Period. Use the command ~I:ReadyLn=2 to configure
the Data Ready Pulse Width for approx 1ms.