LaserSpeed 8000/9000 I/O Module Instruction Handbook
Operation
Part No. 93342 / Drawing No. 0921-01516 Page 70 of 84 Revision E (Dec 2013)
Read Setup Cycle
READ_SETUP PUV Bit 1
(Sent from Master)
READ_STATUS PUV Bit 1
(Sent from I/O Module)
Event
Note: MEASUREMENT DATA IS NOT VALID BETWEEN EVENTS A AND C
Event A
Profibus Master Sets READ_SETUP bit (PUV bit 1) to 1.
I/O Module reads this bit, and begins reading setup from
the LaserSpeed gauge.
Event B
I/O Module sets READ_STATUS bit to 1, indicating that
settings in the current Data Exchange message are valid.
Event C
Profibus Master sets READ_SETUP bit back to 0
Event D
I/O Module sets READ_STATUS bit back to 0
A
B
C
D