Page #83 background imageLoading...
Page #83 background image
LaserSpeed 8000/9000 I/O Module Instruction Handbook
Specifications
Part No. 93342 / Drawing No. 0921-01516 Page 83 of 84 Revision E (Dec 2013)
Protocol version: ver. 1.10
Protocol stack supplier: SIEMENS
Extended functions supported: Diagnostics & User Parameter data,
accessed via mailbox telegram.
Auto baud rate detection supported. Baud rate range: 9.6 kbit-12Mbit
Hardware prepared for DP-V1 extensions.
Save/Load configuration in Flash supported.
Enclosure
IP50
Environmental Conditions
Indoor use
Altitude up to 2000m
Temperature 5C to 40C
Maximum relative humidity 80% for temperatures up to 31C decreasing
linearly to 50% relative humidity at 40C
MAINS supply voltage fluctuations up to 10% of nominal voltage
Transient over-voltage typically present on MAINS supply. NOTE: The
normal level of transient over-voltages is impulse withstand (over-
voltage) CATEGORY II of IED 60364-4-443.
Applicable rated pollution degree 2.