If the top of the bar code data is not the code set selection character,
the printer stops command processing and processes the following
data as normal data.
λ
λ
If the combination of "{" and the following character does not apply
any special character, the printer stops command processing and
processes the following data as normal data.
If the printer receives characters that cannot be used in the special
code set, the printer stops command processing and processes the
following data as normal data.
The printer does not print HRI characters that correspond to the shift
characters or code set selection characters.
λ
HRI character for the function character is space.
HRI characters for the control character (<00>H to <1F>H and
<7F>H) are space.
Be sure to keep spaces on both right and left sides of a bar code.
(Spaces are different depending on the types of the bar code.)
GS H, GS h, GS w
Set bar code printing left space
29 120 n
1D 78 n
The print bar code staring positions is: 0→255
8.2.8 Miscellaneous Function Command
Setting Control Parameter Command
55 n1 n2 n3
37 n1 n2 n3
Set “max heating dots”,” heating time”, “heating interval”
n1=0-255 Max printing dots, Unit(8dots),Default:7(64 dots)
n2=3-255 Heating time, Unit(10us),Default:80(800us)
n3=0-255 Heating interval, Unit(10us),Default:2(20us)
λ
λ
The more max heating dots, the more peak current will cost when
printing, the faster printing speed. The max heating dots is 8*(n1+1)
The more heating time, the more density, but the slower printing
speed. If heating time is too short, blank page may occur.
The more heating interval, the clearer, but the slower printing speed.