Descaling the water tank
1. Fill the water tank
9
with descaling solution up to the “Max.” marking
7
.
2. Leave for one hour.
3. Rinse out the water tank
9
with running water.
4. Repeat this procedure if necessary.
8.7 Storage
When you are not using the device, we recommend that you carry out the following actions:
1. Empty any remaining water from the water tank
9
.
2.
Dry the filter
5
using the filter drying function (see section “8.1 Filter drying function”) or allow it to air dry.
3. Clean the filter
5
, water tank
9
, filter holder
8
and water level sensor
6
.
4. Store the air humidifier in its original packaging and in a dry environment.
5. Store the humidifier without weighing it down.
9. ACCESSORIES AND REPLACEMENT PARTS
To purchase accessories and replacement parts, please visit www.beurer.com or contact the correspond-
ing service address (according to the service address list) in your country. Accessories and replacement
parts are also available from retailers.
Designation Item number and/or order number
Replacement filter 110.005
10. WHAT IF THERE ARE PROBLEMS?
Problem Possible cause Solution
Air humidifier
will not turn on.
Mains plug not plugged in
Insert the mains plug into a suitable socket.
Motor unit not seated properly on
water tank
Check for correct positioning. There must
be no gap between the motor unit and the
water tank.
Water tank is empty Fill the water tank
The air humidifi
-
er does not start
The desired target humidity has
already been reached or exceeded
If you want a higher target humidity level,
set this using the target humidity button (see
section “7.2 Setting target humidity”).
Insucient air
flow
Filter dirty
Clean the filter (see section “8.2 Cleaning
the filter”) and/or descale (if necessary
replace).
Blocked air inlet or outlet Check air inlet/air outlet
The air humidifi
-
er is very noisy
Foreign object in air inlet or air outlet
Pull out the mains plug and remove foreign
bodies from the air inlet/air outlet.
Filter clogged
Clean the filter (see section “8.2 Cleaning
the filter”) and/or descale (if necessary
replace).
Air humidifier is not standing on a
flat and level surface
Place the air humidifier on a level and flat
surface.

Table of Contents